Rondo DUO® Seismic Ceiling Wizard - Australia PRELIMINARY DESIGN ONLY

Seismic v2.0 (2017) - {{ country }} {{ product }}
  • {{ product }} seismic design to:
  • AS/NZS 1170.0:2002 Structural Design Actions - Part 0: General Principles
  • AS/NZS 2785:2000 Suspended Ceilings - Design and Installation
  • AS 1170.4:2007 Structural Design Actions - Part 4: Earthquake Actions in {{ country === "au" ? "Australia" : "New Zealand" }};
    (inc. Amendment 1) Section 8: Design of parts and components
go back get assistance

building data

Geometry Data


m
m
m
m
m







Rondo specific engineering design required for plenum height above 1.7m

Tile Weight Data

kg/m2

Insulation Load Data

kg/m2

Service Load Data

kg/m2

{{ product }}® Weight Data

{{ product }}® Grid Weight   {{ fixed_grid_weight.toFixed(3) }} kg/m2


{{ product }}® Geometry Data

Main-Tee DUO 1
Cross-Tee {{ duo_system_types[duo_system_type].crossTee }}
Main-Tee Spacing [A] {{ nan(duo_system_types[duo_system_type].mainTeeSpacing,3) }} m
Cross-Tee Spacing [B] {{ nan(duo_system_types[duo_system_type].crossTeeSpacing,3) }} m
Main-Tee Span [C] {{ "1.200" }} m

Vertical Capacity Check

Total Ceiling Weight [G] {{ equivalent_ceiling_weight && nan(equivalent_ceiling_weight,3) }} kg/m2
Allowable Ceiling Weight [G] {{ allowable_ceiling_weight && allowable_ceiling_weight.toFixed(3) }} kg/m2

Vertical Capacity ok? {{ vertical_capacity }}

Please select a location to continue


Whilst every care has been taken in the preparation of Rondo Wizards, products and systems do change over time, and interpretations may vary, which means Rondo Building Services Pty Ltd cannot accept liability for the accuracy of information supplied (or lack thereof), or any consequences which happen as a result. Rondo Wizards are intended as a guide only and do not replace professional judgement. Installation of Rondo products must also be in accordance with the Rondo Professional Design Manual which is also available on the Rondo website. Design assumes ceilings are installed in accordance with the Rondo Professional Design Manual. Walls are to be checked independently.

TOTAL SEISMIC WEIGHT

Total Seismic Weight [Wp] {{ total_seismic_weight.toFixed(2) }} kg/m2

Seismic Force Calculation

YES NO
Hazard Factor [Z] {{hazard_factor.au && hazard_factor.au.toFixed(3)}}
Annual Probability of Exceedance {{exceedance_factor}}
Probability Factor [kp] {{probability_factor[country].toFixed(3)}}
Spectral Shape Factor [Ch(0)] {{spectral_factor && spectral_factor.toFixed(3)}}
Height Amplification Factor [ax] {{height_factor.toFixed(3)}}
Component Importance Factor [Ic] {{importance_factor.toFixed(3)}}
Component Amplifiction Factor [ac] {{amplification_factor.toFixed(3)}}
Component Ductility Factor [Rc] {{ductility_factor.toFixed(3)}}
Connection Ductility Factor [Rc] {{connection_ductility_factor.toFixed(3)}}
Connection Ductility Factor [Rc] {{connection_ductility_factor.toFixed(3)}}
Horizontal Seismic Force [Fc] {{horizontal_seismic_force_wc && horizontal_seismic_force_wc[country]}} % Wc
  {{horizontal_seismic_force && horizontal_seismic_force[country]}} kg/m2

Room dimensions

m
m

PERIMETER FIXING

Main-Tee Capacity {{ duo_wall_angle_capacity[duo_wall_angle].mainTee }} kg
Cross-Tee Capacity {{ duo_wall_angle_capacity[duo_wall_angle].crossTee }} kg
Max Main-Tee Length {{ nan(max_maintee_length,3) }} m
Max Cross-Tee Length {{ nan(max_crosstee_length,3) }} m

Can perimeter fixing option be used? Yes No, use plenum bracing solution

plenum bracing

Dropper Type {{bracing_types_for_product[bracing_type].dropper}}
Diagonals Type {{bracing_types_for_product[bracing_type].diagonals}}
Brace Capacity {{ brace_capacity }} kg
Max Area Per Brace {{ nan(max_area_per_brace) }} m2
kg/m2
Distance between Top Cross Rail Spacings [B] {{ plenum_bracing.spacing_main_tees }} m
Spacing Along Top Cross Rails [C] {{ plenum_bracing.spacing_cross_tees }} m
Actual Area Per Brace {{ plenum_bracing.area }} m2
Minimum Brace Required {{ plenum_bracing.min_braces }}

Request a quote

Your Distributor: {{ supplier.selected.name }} - {{ supplier.selected.address }} - {{ supplier.selected.postcode }}

Choose one of the nearest distributors


Please note: If your country is not listed we don't service your region.

Whilst every care has been taken in the preparation of Rondo Wizards, products and systems do change over time, and interpretations may vary, which means Rondo Building Services Pty Ltd cannot accept liability for the accuracy of information supplied (or lack thereof), or any consequences which happen as a result. Rondo Wizards are intended as a guide only and do not replace professional judgement. Installation of Rondo products must also be in accordance with the Rondo Professional Design Manual which is also available on the Rondo website. Design assumes ceilings are installed in accordance with the Rondo Professional Design Manual. Walls are to be checked independently.