rondo worldwide

Stay connected with Rondo

Rondo KEY-LOCK® Seismic Ceiling Wizard - New Zealand PRELIMINARY DESIGN ONLY

Seismic v2.0 (2017) - Rondo KEY-LOCK® ({{ country }})
  • AS/NZS 1170.0:2002 Structural Design Actions - Part 0: General Principles
  • AS/NZS 2785:2000 Suspended Ceilings - Design and Installation
  • AS 1170.4:2007 Structural Design Actions - Part 4: Earthquake Actions in Australia; (inc. Amendment 1) Section 8: Design of parts and components
  • AS/NZS 1170.0:2002 Structural Design Actions - Part 0: General Principles (inc. Amendments 1 - 5)
  • AS/NZS 2785:2000 Suspended Ceilings - Design and Installation
  • NZS 1170.5:2004 Structural Design Actions Part 5: Earthquake actions - New Zealand (inc. Amendment 1) Section 8: Requirements for parts and components
go back get assistance

building data

Geometry Data


m
m
m
m
m







Rondo specific engineering design required for plenum height above 1.7m

Lining Weight Data

kg/m2

Total Lining Weight {{ total_lining_weight }} kg/m2

Insulation Load Data

kg/m2

Service Load Data

kg/m2

KEY-LOCK® Weight Data

KEY-LOCK® Grid Weight {{ fixed_grid_weight.toFixed(3) }} kg/m2


KEY-LOCK® Geometry Data

Vertical Capacity Check

Total Ceiling Weight [G] {{ equivalent_ceiling_weight && nan(equivalent_ceiling_weight,3) }} kg/m2
Allowable Ceiling Weight [G] {{ allowable_ceiling_weight && allowable_ceiling_weight.toFixed(3) }} kg/m2

Vertical Capacity ok? {{ vertical_capacity }}

Please select a location to continue


Whilst every care has been taken in the preparation of Rondo Wizards, products and systems do change over time, and interpretations may vary, which means Rondo Building Services Pty Ltd cannot accept liability for the accuracy of information supplied (or lack thereof), or any consequences which happen as a result. Rondo Wizards are intended as a guide only and do not replace professional judgement. Installation of Rondo products must also be in accordance with the Rondo Professional Design Manual which is also available on the Rondo website. Design assumes ceilings are installed in accordance with the Rondo Professional Design Manual. Walls are to be checked independently.

TOTAL SEISMIC WEIGHT

Total Seismic Weight [Wp] {{ total_seismic_weight.toFixed(2) }} kg/m2

Seismic Force Calculation

Limit State for Design
Annual Probability of Exceedance {{exceedance_factor__view}}
Spectral Shape Factor [Ch(0)] {{nan(spectral_factor,3)}}
Hazard Factor [Z] {{nan(hazard_factor.nz,3)}}
Return Period Factor [Rs/Ru] {{nan(return_period__view,3) }}
Distance to Nearest Fault [D] {{distance_nearest_fault__view}} km
Estimated Structural Period [T] {{estimated_period__view.toFixed(3)}} s
Maximum Near Fault Factor [Nmax(T)] {{maximum_near_fault__view}}
Near Fault Factor [N(T,D)] {{near_fault_factor__view.toFixed(3)}}
Elastic Site Hazard Spectrum [C(0)] {{elastic_site__view.toFixed(3)}}
Floor Height Coefficient [CHi] {{floor_height_coefficient.toFixed(3)}}
Part Spectral Shape Factor [Ci(Tp)] {{part_spectral_shape.toFixed(3)}}
Design Response Cofficent for Parts [Cp(Tp)] {{response_coefficient__view.toFixed(3)}}
Ductility of Part [µp]
Part Horizontal Design Coefficient [Cph] {{part_horizontal_design__view}}
Part Risk Factor [Rp] {{part_risk_factor__view}}
Horizontal Seismic Force [Fph] {{horizontal_seismic_force_wc__view[country]}} % Wc
{{horizontal_seismic_force__view && horizontal_seismic_force__view[country]}} kg/m2

Room dimensions

m
m

PERIMETER FIXING

TCR Wall Track
FC Wall Track
Wall Track 141 Wall Track
127 TCR Capacity 96.300 kg
129 FC Capacity 60.600 kg
Max 127 TCR Length {{ max_127_tcr_length }} m
Max 129 FC Length {{ max_129_fc_length }} m

Can perimeter fixing option be used? Yes No, use plenum bracing solution

plenum bracing

Dropper Type {{bracing_types_for_product[bracing_type].dropper}}
Diagonals Type {{bracing_types_for_product[bracing_type].diagonals}}
Brace Capacity {{ brace_capacity }} kg
Max Area Per Brace {{ nan(max_area_per_brace) }} m2
kg/m2
Distance between Top Cross Rail Spacings [B] {{ plenum_bracing.spacing_main_tees }} m
Spacing Along Top Cross Rails [C] {{ plenum_bracing.spacing_cross_tees }} m
Actual Area Per Brace {{ plenum_bracing.area }} m2
Minimum Brace Required {{ plenum_bracing.min_braces }}

Request a quote

Your Distributor: {{ supplier.selected.name }} - {{ supplier.selected.address }} - {{ supplier.selected.postcode }}

Choose one of the nearest distributors


Please note: If your country is not listed we don't service your region.

Whilst every care has been taken in the preparation of Rondo Wizards, products and systems do change over time, and interpretations may vary, which means Rondo Building Services Pty Ltd cannot accept liability for the accuracy of information supplied (or lack thereof), or any consequences which happen as a result. Rondo Wizards are intended as a guide only and do not replace professional judgement. Installation of Rondo products must also be in accordance with the Rondo Professional Design Manual which is also available on the Rondo website. Design assumes ceilings are installed in accordance with the Rondo Professional Design Manual. Walls are to be checked independently.